Search form

Clone of Meralgia paraesthetica

Patient Positioning

Patient supine, leg may be in slight external rotation.

Probe Positioning

Place the transducer on almost transverse planes over the anterior superior iliac spine. 

 

note: perineural infiltration of the lateral femoral cutaneous nerve

n: lateral femoral cutaneous nerve

asis: anterior superior ilac spine